Nvidia 4 Manuale Utente

Navigare online o scaricare Manuale Utente per Hardware Nvidia 4. Nvidia 4 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 159
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti

Sommario

Pagina 1 - MediaShield User’s

ForceWare SoftwareMediaShield User’s GuideVersion 4.0NVIDIA CorporationMarch 24, 2006

Pagina 2

6 MediaShield User’s Guide – Version 4.0CHAPTER 1About NVIDIA® MediaShield™RAID 1How RAID 1 WorksIn a RAID 1 array, every read and write is carried ou

Pagina 3 - Table of Contents

96 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility3 Right click on Stripe Mirroring and select “Co

Pagina 4

NVIDIA Corporation 97CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 Click Next and the following screen shot will appear:Figure 3.91RA

Pagina 5 - MEDIASHIELD™

98 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility7 Click Next, then click Finish. 8 Click on Stri

Pagina 6 - ™ versions:

NVIDIA Corporation 99CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 0+1 to RAID 0+1 The following example shows you

Pagina 7 - Operating System Support

100 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility3 Right click on Stripe Mirroring and select “C

Pagina 8 - RAID Arrays

NVIDIA Corporation 101CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 Click Next and the following screen shot will appear:Figure 3.97R

Pagina 9 - Figure 1.1

102 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility7 Select the disks that you want to migrate (in

Pagina 10 - Figure 1.2

NVIDIA Corporation 103CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 0 to RAID 5The following example shows you how

Pagina 11 - Figure 1.3

104 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility3 Right click on the newly created striped arra

Pagina 12 - Figure 1.4

NVIDIA Corporation 105CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 Click Next and the following screen shot will appear:Figure 3.103

Pagina 13 - Figure 1.5

NVIDIA Corporation 7CHAPTER 1About NVIDIA® MediaShield™RAID 0+1How RAID 0+1 WorksRAID 0 drives can be mirrored using RAID 1 techniques, resulting in a

Pagina 14 - NVIDIA MediaShield Features

106 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityIn this example, we are adding one disk (which

Pagina 15 - Features and Benefits Summary

NVIDIA Corporation 107CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityThe Migrating ProcessAs you can see from the screen shot above, a t

Pagina 16 - About NVIDIA® MediaShield™

108 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 1 to RAID 5The following ex

Pagina 17 - Setting Up the BIOS

NVIDIA Corporation 109CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAfter selecting “Convert Array...” the following screen shot will a

Pagina 18 - Figure 2.2

110 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 For the “New RAID Mode:” entry select RAID 5

Pagina 19 - Figure 2.3

NVIDIA Corporation 111CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility7 Select one of the disks and click Next, then Finish.. Figure 3.11

Pagina 20 - Figure 2.4

112 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 0+1 to RAID 5The following

Pagina 21 - Figure 2.5

NVIDIA Corporation 113CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAfter selecting “Convert Array...” the following screen shot will a

Pagina 22 - Figure 2.7

114 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility6 Click Next, then Finish and the following scr

Pagina 23 - Figure 2.8

NVIDIA Corporation 115CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 5 to RAID 0The following example shows you how

Pagina 24 - Figure 2.9

8 MediaShield User’s Guide – Version 4.0CHAPTER 1About NVIDIA® MediaShield™RAID 5How RAID 5 WorksRAID 5 stripes both data and parity information acros

Pagina 25

116 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAfter selecting “Convert Array...” the followin

Pagina 26 - 4 Press Enter

NVIDIA Corporation 117CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 Click Next, then Finish. In this example, the WD360GD was chosen

Pagina 27 - Figure 2.12

118 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 5 to RAID 0+1The following

Pagina 28 - Figure 2.13

NVIDIA Corporation 119CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAfter selecting “Convert Array...” the following screen shot will a

Pagina 29 - (Obsolete)

120 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 Select a Free Disk, then Click Next, then Fin

Pagina 30 - Figure 2.15

NVIDIA Corporation 121CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 5 to RAID 5The following example shows you how

Pagina 31 - Figure 2.17

122 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAfter selecting “Convert Array...” the followin

Pagina 32 - Figure 2.18

NVIDIA Corporation 123CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 Select a Free Disk, then Click Next, then Finish. Figure 3.133New

Pagina 33 - Installing the RAID Drivers

124 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityHot Plug ArrayNVIDIA MediaShield arrays can be

Pagina 34 - Figure 2.21

NVIDIA Corporation 125CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility1 Launch MediaShield and click on “Hot Plug Array” and the followin

Pagina 35 - NVIDIA Corporation 31

NVIDIA Corporation 9CHAPTER 1About NVIDIA® MediaShield™JBODHow JBOD WorksJBOD stands for “Just a Bunch of Disks”. Each drive is accessed as if it were

Pagina 36 - HAPTER 2

126 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility4 Click Next and the following screen shot will

Pagina 37

NVIDIA Corporation 127C HAPTERINITIALIZING, REBUILDING, ANDSYNCHRONIZING RAID ARRAYSThis chapter describes the following MediaShield tasks: • Initiali

Pagina 38 - Figure 3.2

128 MediaShield User’s Guide – Version 4.0CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID ArraysInitializing a RAID ArrayInitializing a RAID

Pagina 39 - Spanning (JBOD) RAID Array

NVIDIA Corporation 129CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID Arrays6 Click Next again and the following screen shot will appear:Fig

Pagina 40 - Figure 3.6

130 MediaShield User’s Guide – Version 4.0CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID ArraysFigure 4.4Clearing System Data and Initializ

Pagina 41 - Setting Up a Spare RAID Disk

NVIDIA Corporation 131CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID ArraysThe Initialization ProcessAs you can see from the screen shot ab

Pagina 42 - Figure 3.7

132 MediaShield User’s Guide – Version 4.0CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID ArraysRebuilding a RAID ArrayRebuilding is the pro

Pagina 43 - Figure 3.8

NVIDIA Corporation 133CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID Arrays2 Right-click on Mirroring.The popup menu appears.Figure 4.7Arra

Pagina 44 - Figure 3.10

134 MediaShield User’s Guide – Version 4.0CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID Arrays4 Click Next.The Disk Selection page appears

Pagina 45 - Figure 3.11

NVIDIA Corporation 135CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID Arrays6 Click Finish.The array rebuilding starts after a few seconds,

Pagina 46 - Figure 3.13

10 MediaShield User’s Guide – Version 4.0CHAPTER 1About NVIDIA® MediaShield™Summary of RAID ConfigurationsNVIDIA MediaShield FeaturesAdditional RAID F

Pagina 47 - Creating RAID Arrays

136 MediaShield User’s Guide – Version 4.0CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID ArraysMore About Rebuilding Arrays• Rebuilding Occ

Pagina 48 - Figure 3.15

NVIDIA Corporation 137CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID ArraysSynchronizing a RAID ArraySynchronizing an array will force a re

Pagina 49 - Click Finish

138 MediaShield User’s Guide – Version 4.0CHAPTER 4Initializing, Rebuilding, and Synchronizing RAID ArraysFigure 4.16Synchronize Array Wizard—Welcome

Pagina 50 - Capacity

NVIDIA Corporation 139C HAPTERUSING DISK ALERTAbout Disk AlertThe RAID manager application includes a disk alert feature that provides a graphical ind

Pagina 51 - Figure 3.16

140 MediaShield User’s Guide – Version 4.0CHAPTER 5Using Disk AlertDisk Alert ExamplesFigure 5.1 through Figure 5.3 illustrate how the Disk Alert feat

Pagina 52 - Figure 3.18

NVIDIA Corporation 141CHAPTER 5Using Disk AlertExample of a Degraded ArrayFigure 5.2 shows a yellow SATA port indicating that an array has been degrad

Pagina 53 - Figure 3.20

142 MediaShield User’s Guide – Version 4.0CHAPTER 5Using Disk AlertExample of a Failed Drive Figure 5.3 shows a red SATA port indicating that a drive

Pagina 54 - Figure 3.22

NVIDIA Corporation 143C HAPTERMEDIASHIELD RAID FREQUENTLY ASKEDQUESTIONSThe FAQ in this chapter are organized by the following categories:• “Basic RAI

Pagina 55 - Figure 3.23

144 MediaShield User’s Guide – Version 4.0CHAPTER 6MediaShield RAID Frequently Asked QuestionsBasic RAID Questions• What is RAID?RAID stands for Redun

Pagina 56 - Figure 3.25

NVIDIA Corporation 145CHAPTER 6MediaShield RAID Frequently Asked Questions• Why is the cumulative size of a RAID 0 (Stripe) or RAID 0+1 (Stripe-Mirror

Pagina 57 - Figure 3.27

NVIDIA Corporation 11CHAPTER 1About NVIDIA® MediaShield™having to go through multiple steps. The migrating feature gives the user an upgradeable optio

Pagina 58 - Figure 3.28

146 MediaShield User’s Guide – Version 4.0CHAPTER 6MediaShield RAID Frequently Asked QuestionsDedicated Disk Questions• Can I assign a dedicated disk

Pagina 59 - Figure 3.30

NVIDIA Corporation 147CHAPTER 6MediaShield RAID Frequently Asked Questions• Assign a dedicated disk to RAID 1, RAID 0+1 and RAID 5• Remove a dedicated

Pagina 60 - Figure 3.32

148 MediaShield User’s Guide – Version 4.0CHAPTER 6MediaShield RAID Frequently Asked Questions

Pagina 61 - Figure 3.34

NVIDIA Corporation 149C HAPTERMEDIASHIELD APPLICATION NOTESThis chapter includes several application notes that address specific issues that may be en

Pagina 62 - Figure 3.35

150 MediaShield User’s Guide – Version 4.0CHAPTER 7MediaShield Application NotesWindows 2000 Limitation with Bootable RAIDProblemIn Windows 2000 (Serv

Pagina 63 - Figure 3.37

NVIDIA Corporation 151CHAPTER 7MediaShield Application NotesUsing GHOST with NVIDIA RAIDProblemGHOST can interface with hard disk controllers by acces

Pagina 64 - Figure 3.39

152 MediaShield User’s Guide – Version 4.0CHAPTER 7MediaShield Application NotesHow to Build a Slipstream XP-SP2 CDProblemCreate a CD that will instal

Pagina 65 - Figure 3.41

NVIDIA Corporation 153CHAPTER 7MediaShield Application NotesAdd NVIDIA Drivers1 Extract the NVIDIA driver files from the nForce package using ‘-x’ opt

Pagina 66 - Figure 3.42

154 MediaShield User’s Guide – Version 4.0CHAPTER 7MediaShield Application Notes GenNvRaidDisk = "nvraid" *_NVRAIDBUS

Pagina 67 - Figure 3.44

NVIDIA Corporation 155CHAPTER 7MediaShield Application Notes• XP Professional OEM enter WXPOEM_EN• XP Home OEM enter WXHOEM_EN• Select everything from

Pagina 68 - Figure 3.46

12 MediaShield User’s Guide – Version 4.0CHAPTER 1About NVIDIA® MediaShield™

Pagina 69 - Figure 3.48

NVIDIA Corporation 13C HAPTERSETTING UP YOUR RAID CONFIGURATIONThis chapter provides instructions for:• Setting Up a Non-Bootable RAID Array• Setting

Pagina 70 - Figure 3.49

14 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID ConfigurationThe BIOS CMOS Setup Utility window appears. Figure 2.1BIOS CMOS Se

Pagina 71 - Figure 3.51

NVIDIA Corporation 15CHAPTER 2Setting Up Your RAID ConfigurationThe RAID Config window appears.Figure 2.3RAID Config Window4 From the RAID Config wind

Pagina 72 - Figure 3.52

NVIDIA Applications MediaShield User’s Guide Version 4.0Published byNVIDIA Corporation 2701 San Tomas ExpresswaySanta Clara, CA 95050NoticeALL NVIDIA

Pagina 73 - General Migrating Principles

16 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID ConfigurationInstalling the NVIDIA MediaShield Software Under WindowsThis secti

Pagina 74 - HAPTER 3

NVIDIA Corporation 17CHAPTER 2Setting Up Your RAID ConfigurationUsing RAID Arrays Under WindowsAfter rebooting the PC, initialize the newly created ar

Pagina 75

18 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID Configuration3 Click Next.The Select Disks to Initialize window appears. Figure

Pagina 76 - Figure 3.53

NVIDIA Corporation 19CHAPTER 2Setting Up Your RAID Configuration5 Check the disk in the list if you want to make the array a dynamic disk, then click

Pagina 77 - Figure 3.55

20 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID Configuration6 Click Finish.The Computer Management window appears. Figure 2.9C

Pagina 78 - Figure 3.57

NVIDIA Corporation 21CHAPTER 2Setting Up Your RAID ConfigurationSetting Up a Bootable RAID ArrayThis section explains how to configure a bootable RAID

Pagina 79 - Figure 3.59

22 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID ConfigurationThe Integrated Peripherals screen (or a screen similar to it) appe

Pagina 80 - More About This Example

NVIDIA Corporation 23CHAPTER 2Setting Up Your RAID ConfigurationThe RAID Config screen appears.Figure 2.12RAID Config Screen5 From the RAID Config win

Pagina 81 - Figure 3.61

24 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID ConfigurationConfiguring the NVIDIA RAID BIOSThe NVIDIA RAID BIOS setup lets yo

Pagina 82 - Figure 3.63

NVIDIA Corporation 25CHAPTER 2Setting Up Your RAID ConfigurationUnderstanding the Define a New Array WindowUse the Define a New Array window to• Selec

Pagina 83 - Figure 3.65

NVIDIA Corporation iNVIDIA Applications MediaShield User’s Guide v4.01.About NVIDIA® MediaShield™. . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 84 - Figure 3.66

26 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID ConfigurationAssigning the DisksThe disks that you enabled from the RAID Config

Pagina 85 - Figure 3.67

NVIDIA Corporation 27CHAPTER 2Setting Up Your RAID ConfigurationCompleting the RAID BIOS Setup1 After assigning your RAID array disks, press F7.The Cl

Pagina 86 - Figure 3.69

28 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID Configuration3 Use the arrow keys to select the array that you want to set up,

Pagina 87 - Figure 3.71

NVIDIA Corporation 29CHAPTER 2Setting Up Your RAID ConfigurationInstalling the RAID DriversYour system may come with a Windows install CD that already

Pagina 88 - Figure 3.73

30 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID ConfigurationThe following Windows Setup screen appears:Figure 2.20Windows Setu

Pagina 89 - Figure 3.74

NVIDIA Corporation 31CHAPTER 2Setting Up Your RAID ConfigurationBe sure to leave the floppy disk inserted in the floppy drive until the blue screen po

Pagina 90 - Figure 3.75

32 MediaShield User’s Guide – Version 4.0CHAPTER 2Setting Up Your RAID Configuration

Pagina 91 - Figure 3.77

NVIDIA Corporation 33C HAPTERUSING THE NVIDIA MEDIASHIELD RAIDMANAGEMENT UTILITYAbout the MediaShield RAID Management UtilityThe MediaShield RAID soft

Pagina 92 - Figure 3.79

34 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityViewing RAID Array Configurations To view your R

Pagina 93 - Figure 3.80

NVIDIA Corporation 35CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityStriped RAID ArrayFigure 3.3 shows an example of a two hard drive st

Pagina 94 - Figure 3.81

NVIDIA Corporation iiNVIDIA Applications MediaShield User’s Guide v4.0Synchronizing a RAID Array. . . . . . . . . . . . . . . . . .

Pagina 95 - Figure 3.83

36 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMirrored RAID Array and Striped RAID Array Figur

Pagina 96 - Figure 3.85

NVIDIA Corporation 37CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilitySetting Up a Spare RAID Disk You can designate a hard drive to be us

Pagina 97 - Figure 3.87

38 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAssigning a Free DiskTo mark a disk as free, or

Pagina 98

NVIDIA Corporation 39CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAssigning a Dedicated DiskTo mark a disk as dedicated, or reserve it

Pagina 99 - Figure 3.88

40 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility2 Select Designate Spare from the menu to launch

Pagina 100 - Figure 3.90

NVIDIA Corporation 41CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility4 From the Free Disk Selection page, select one of the two free disk

Pagina 101 - Figure 3.92

42 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAs shown in Figure 3.12, the ST380011A drive is

Pagina 102 - Figure 3.93

NVIDIA Corporation 43CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityCreating RAID ArraysThis section covers use of the MediaShield Creat

Pagina 103 - Figure 3.94

44 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityUsing the MediaShield Create WizardThe MediaShie

Pagina 104 - Figure 3.96

NVIDIA Corporation 45CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAs shown in Figure 3.15, there are three options:• Protection• Capac

Pagina 105 - Figure 3.98

NVIDIA Corporation 1C HAPTERABOUT NVIDIA® MEDIASHIELD™NVIDIA brings Redundant Array of Independent Disks (RAID) technology—which is used by the world’

Pagina 106 - Figure 3.99

46 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityCapacitySelect this option and MediaShield will

Pagina 107 - Figure 3.100

NVIDIA Corporation 47CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityCreating a Striped ArrayMediaShield can be used to create a striped

Pagina 108 - Figure 3.102

48 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility4 Click the RAID Mode list arrow and select Stri

Pagina 109 - Figure 3.104

NVIDIA Corporation 49CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility6 Select the two disks that you want to include in the stripe set. I

Pagina 110 - Figure 3.106

50 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility8 To clear all system data from the drives click

Pagina 111 - The Migrating Process

NVIDIA Corporation 51CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityCreating a Mirrored ArrayThe MediaShield application can be used to

Pagina 112 - Figure 3.108

52 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityIn this example the upper two disks were selecte

Pagina 113 - Figure 3.110

NVIDIA Corporation 53CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility6 To clear all system data from the drives click on Next and the fol

Pagina 114 - Figure 3.112

54 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityCreating a Stripe Mirroring ArrayMediaShield can

Pagina 115 - Figure 3.113

NVIDIA Corporation 55CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility4 Click on “RAID Mode:” and select “Stripe Mirroring” while leaving

Pagina 116 - Figure 3.115

2 MediaShield User’s Guide – Version 4.0CHAPTER 1About NVIDIA® MediaShield™System RequirementsHardware SupportNVIDIA MediaShield supports the followin

Pagina 117 - Figure 3.117

56 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility6 Select the four drives that you want to use in

Pagina 118 - Figure 3.118

NVIDIA Corporation 57CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility8 To clear all system data from the drives click on Next and the fol

Pagina 119 - Figure 3.120

58 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityCreating a Spanning Array MediaShield can be use

Pagina 120 - Figure 3.122

NVIDIA Corporation 59CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility4 Click the RAID Mode list arrow and select “Spanning” while leaving

Pagina 121 - Figure 3.123

60 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility6 Select the two drives that you want to use in

Pagina 122 - Figure 3.125

NVIDIA Corporation 61CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility8 To clear all system data from the drives click on Next and the fol

Pagina 123 - Figure 3.127

62 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityCreating a RAID 5 Array MediaShield can be used

Pagina 124 - Figure 3.128

NVIDIA Corporation 63CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility4 Click the RAID Mode list arrow and select RAID 5, and leave the “S

Pagina 125 - Figure 3.130

64 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility6 Select the three disks that you want to includ

Pagina 126 - Figure 3.132

NVIDIA Corporation 65CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility8 To clear all system data from the drives click Next.Figure 3.47Com

Pagina 127 - Figure 3.133

NVIDIA Corporation 3CHAPTER 1About NVIDIA® MediaShield™Operating System SupportNVIDIA MediaShield supports the following operating systems:•Windows® X

Pagina 128 - Hot Plug Array

66 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityDeleting a RAID ArrayMediaShield can be used to

Pagina 129 - Figure 3.135

NVIDIA Corporation 67CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAfter the “Delete Array...” has been selected, the following screen

Pagina 130 - Figure 3.136

68 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility3 Click Finish and the array will be deleted and

Pagina 131 - SYNCHRONIZING RAID ARRAYS

NVIDIA Corporation 69CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating From One RAID Array to AnotherIn a traditional RAID enviro

Pagina 132 - Figure 4.1

70 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilitySpecific Migrating RequirementsThe following tab

Pagina 133 - Figure 4.3

NVIDIA Corporation 71CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating InstructionsThis sections includes specific instructions f

Pagina 134 - Figure 4.5

72 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 0 to RAID 0—Adding a Disk to

Pagina 135 - The Initialization Process

NVIDIA Corporation 73CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility3 Right click on the newly created striped array (or existing stripe

Pagina 136 - Figure 4.6

74 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 Click Next and the following screen shot will

Pagina 137 - Figure 4.8

NVIDIA Corporation 75CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility7 Select the disk (or disks) that you want to add to the existing st

Pagina 138 - Figure 4.10

4 MediaShield User’s Guide – Version 4.0CHAPTER 1About NVIDIA® MediaShield™RAID ArraysThis section describes the following types of RAID arrays that M

Pagina 139 - Figure 4.13

76 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityThe Migrating ProcessAs you can see from the scr

Pagina 140 - Figure 4.14

NVIDIA Corporation 77CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 0 (with One Disk) to RAID 1 (with Two Disks)The

Pagina 141 - Figure 4.15

78 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityAfter selecting “Convert Array...” the following

Pagina 142 - Figure 4.17

NVIDIA Corporation 79CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 For the “New RAID Mode:” entry select Mirror as shown in the follo

Pagina 143 - USING DISK ALERT

80 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility7 Select one of the disks and click Next, then F

Pagina 144 - Figure 5.1

NVIDIA Corporation 81CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 0 to RAID 0+1The following example shows you how

Pagina 145 - Figure 5.2

82 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility3 Right click on the newly created striped array

Pagina 146 - Figure 5.3

NVIDIA Corporation 83CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility4 Click Next and the following screen shot will appear:Figure 3.70RA

Pagina 147 - QUESTIONS

84 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility6 Click Next and the following screen shot will

Pagina 148 - Basic RAID Questions

NVIDIA Corporation 85CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility8 Click Finish, then click the newly created four-disk stripe mirror

Pagina 149 - Rebuilding Arrays Questions

NVIDIA Corporation 5CHAPTER 1About NVIDIA® MediaShield™RAID 0 How RAID 0 WorksIn a RAID 0 array, the controller ʺstripesʺ data across multiple drives

Pagina 150 - Windows RAID Application

86 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 1 to RAID 0The following exa

Pagina 151 - NVIDIA Corporation 147

NVIDIA Corporation 87CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility3 Right click on Mirroring and select “Convert Array...” as shown in

Pagina 152 - HAPTER 6

88 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 Click Next and the following screen shot will

Pagina 153

NVIDIA Corporation 89CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility7 Click Next, then click Finish to complete the process. • If you wa

Pagina 154 - Solution

90 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 1 to RAID 0+1The following e

Pagina 155 - Using GHOST with NVIDIA RAID

NVIDIA Corporation 91CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility3 Right click on Mirroring and select “Convert Array...” as shown in

Pagina 156 - Initial Setup

92 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility5 Click Next and the following screen shot will

Pagina 157 - Add NVIDIA Drivers

NVIDIA Corporation 93CHAPTER 3Using the NVIDIA MediaShield RAID Management Utility7 Click Next and the following screen shot will appear: Figure 3.86F

Pagina 158 - Burning a CD

94 MediaShield User’s Guide – Version 4.0CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityThe Migrating ProcessAs soon as the new four-dis

Pagina 159 - • XP Home OEM enter WXHOEM_EN

NVIDIA Corporation 95CHAPTER 3Using the NVIDIA MediaShield RAID Management UtilityMigrating from RAID 0+1 to RAID 0The following example shows you how

Commenti su questo manuale

Nessun commento